IS-25 Issue: 4 Date: 19.06.12 C/Note: 11759 Page 2 of 3
7. Repeat steps 4 to 6 until the moulding is populated as required. Care should be taken not to
damage any contacts. It is recommended that the moulding be supported by a small fixture
or a hard flat surface. Do not support the mould on any latches fitted, or pressure exerted on
inserting the contacts will bend the latches.
Figure 1
Figure 2 Figure 3
(Correct contact position (Incorrect contact position
- -
Note: Female contact shown
Insertion Tool
Partially
Inserted
Contact
Cable
Groove
Cable
Contact
Moulding
Contact
Moulding
Vedere la pagina 1